39
F3SG-SR
User’s Manual
Chapter
2
PNP/NPN Selection
System Operation and Functions
E
2-4. PNP/NPN Selection
2-4-1. Overview
The F3SG-SR has the PNP/NPN Selection function for the user to select the polarity of the inputs and
outputs between PNP and NPN by changing the wiring. When the F3SG-SR system is set to PNP, the
PNP indicator is illuminated in green.
The F3SG-SR is set to PNP when the 24V/0V line (brown) is connected to +24 VDC and the 0V/24V
line (blue) to 0 V, The F3SG-SR is set to NPN when the 0V/24V line (blue) is connected to +24 VDC
and the 24V/0V line (brown) to 0 V.
When using an Intelligent Tap, wire the F39-JG
A-D sensor connected with CN2 of the Intelligent Tap
in the same way as above.
2-4-2. Setting with Intelligent Tap
The user cannot make any changes to the settings of this function by the DIP Switch on the Intelligent
Tap.
2-4-3. Setting with SD Manager 3
The user cannot make any changes to the settings of this function by the SD Manager 3.
F3SG-SRA
F3SG-SRB
0V/24V (Blue)
+24 VDC
0V
PNP
0V
+24 VDC
NPN
F3SG-SR
emitter
and
receiver
F3SG-SR
emitter
and
receiver
24V/0V (Brown)
24V/0V (Brown)
0V/24V (Blue)
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...