![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123160.webp)
132
Chapter
3
Wiring
F3SG-SR
User’s Manual
Setting with Intelligent Tap
3-3. Wiring
<Internal wiring diagram>
Male
CN2
CN1
Female
RESET/EDM
Yellow
1
1
RESET/EDM
24V/0V
Brown
2
2
+24V
MUTE A/PRE-RESET/PSDI
Gray
3
3
COM(+)
MUTE B
Pink
4
4
COM(-)
OSSD 1
Black
5
5
OSSD 1
OSSD 2
White
6
6
OSSD 2
0V/24V
Blue
7
7
0V
AUX
Red
8
8
AUX
The wire colors are those of the F39-JG
A-D
to be connected to the CN2.
Male
CN3
CN4
Female
L+
Brown
1
1
+24V
DO
White
2
2
TEST
L-
Blue
3
3
0V
C/Q
Black
4
4
COM(+)
Not used
Yellow
5
5
SIO-
The wire colors are those of the XS5F-D521-
DJ0-IL to be connected to the CN3.
CN2
CN3
CN1
CN4