94
Chapter
2
Fixed Blanking
F3SG-SR
User’s Manual
System Operation and Functions
Constraint between fixed blanking zones
More than one fixed blanking zone can be configured adjacently (Figures 1 and 2). But allowable
beams cannot be set adjacently (Figure 3). You cannot overlap fixed blanking zones. (Figure 4)
Limitation for combination with other functions
You can use this function in combination with the Muting, Floating Blanking and Warning Zone
functions at the same time with the SD Manager 3.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
Settings for respective zone have limitations.
Refer to 2-19. Setting Zone Adjacency Conditions for more information.
2-15-2. Factory Default Setting
Fixed Blanking is disabled.
Normal detecting beam
Fixed blanking beam
Allowable beam
Figure 4
Figure 3
Figure 1
Figure 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
(Allowable beam: 1 lower beam)
Fixed blanking zone 1
(Lower 1 allowable beam)
Fixed blanking zone 2
(Upper 1 allowable beam)
Fixed blanking zone 2
Upper
Upper
Upper
Upper
Lower
Lower
Lower
Lower
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...