18
Chapter
1
Ra
tings
a
nd
Spec
if
icat
ions
F3SG-SR
User’s Manual
Overview and Specifications
Maximum cable extension (Load condition: Safety outputs 1 and 2: 60mA, Auxiliary output : 60 mA)
*1. Cable extension when (6) is 10 m
*2. (8) must be 20 m max.
*3. Under the maximum load conditions (safety outputs 1 and 2 of 300 mA per channel and auxiliary output of 100 mA), the cable
extension must be 50% max. of the length listed in the table for the F3SG-
SRA and 80% max. for the F3SG-
SRB.
*4. Conditions exist for the use of the F3SG-
SRA in 2-segment or 3-segment cascade. Refer to
Electrical
–
Safety outputs (OSSD)
.
*5. Not including the Cascading Cable for Extended (F39-JGR3W) and the Root-Plug Cable for Extended (F39-JGR3K).
<Using Y-Joint Plug/Socket Connector (F39-GCNY2)>
Maximum cable extension (Load condition: Safety outputs 1 and 2: 60mA, Auxiliary output : 60 mA)
*1. Cable extension when (5) and (6) are 10 m each
*2. Under the maximum load conditions (safety outputs 1 and 2 of 300 mA per channel and auxiliary output of 100 mA), the cable
extension must be 50% max. of the length listed in the table for the F3SG-
SRA and 80% max. for the F3SG-
SRB.
*3. Conditions exist for the use of the F3SG-
SRA in 2-segment or 3-segment cascade. Refer to
Electrical
–
Safety outputs (OSSD)
.
*4. Not including the Cascading Cable for Extended (F39-JGR3W) and the Root-Plug Cable for Extended (F39-JGR3K).
Sensor
F3SG-
SRA *1 *3
F3SG-
SRB *1 *3
Cascading
Single
2-segment *4
3-segment *4
Single
2-segment
3-segment
(1),(2),(3),(4)
10 m each *5
10 m each *5
(5)
100 m
100 m
(6)+(7)
≤
100 m
≤
100 m
≤
80 m
≤
100 m
≤
100m
≤
100 m
Sensor
F3SG-
SRA *1 *2
F3SG-
SRB *1 *2
Cascading
Single
2-segment *3
3-segment *3
Single
2-segment
3-segment
(1),(2),(3),(4)
10 m each *4
10 m each *4
L: (5)+(7)
(6)+(7)
≤
100 m
≤
70 m
≤
60 m
≤
100 m
≤
90 m
≤
80 m
(5)
(6)
Emitter
Receiver
(1)
(2)
(3)
(4)
Power
supply
(8)
*2
(7)
Power
supply
IO-Link
master
- Optical synchronization
(5)
(6)
Emitter
Receiver
Y-Joint Plug/
Socket Connector
(F39-GCNY2)
L = 100 to 60 m
(1)
(2)
(3)
(4)
(7)
Power
supply
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...