224
Chapter
4
Monitoring with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-4-2. Muting Statistics Information
This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
This function logs and visualizes conditions of F3SG-SR muting operations to help the user adjust
settings of muting input time difference. Also, its statistic calculation allows for optimal settings with
reduced test runs.
On the Top page, click the icon below.
The screen below is displayed.
No.
Function
Description
1
Start (stop) online
monitoring
Retrieves muting input time difference information from the F3SG-SR in real time and
displays it in the analysis data area (No. 10).
2
Retrieve log
Obtains the muting input time difference information saved in F3SG-SR and displays it as
Analysis Data (No. 10) and displays the graph as Graph (No. 11). Pressing this button
switches the safety outputs to the OFF state and the operating state to [Setting state].
3
Open analysis data
Opens a .cvs file saved by the operation (No. 4).
4
Save analysis data
Saves data displayed in the analysis data area (No. 10) as a .csv file. The data saved also
includes other muting input time difference information and sensor information.
5
Clear log
Clears muting time logs saved in the F3SG-SR.
6
Timing chart
Displays a timing chart of time analyzed.
7
Muting input time
difference analysis table
Displays minimum and maximum values of muting setting parameter, assumed data and
measured data, and judgment results on these values.
8
Description on muting
input time difference
analysis table
Displays meanings of abbreviations and judgment results in the table.
A.D.: Assumed Data (the value calculated from M.D. using the standard deviation setting.
The value of zero or less is handled as zero.)
M.D.: Measured Data (the measured value of the time difference from muting input A to
muting input B)
9
Standard deviation setting The range of variation of assumed data can be selected from 2.6 , 3.0 and 6.0 .
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...