![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123376.webp)
348
Chapter
8
Troubleshooting
F3SG-SR
User’s Manual
Appendix
*1. You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
*2. Other indicators than the ERR and MAINT indicators are not illuminated. For details of the error, refer to [Code] and [Error description]
displayed in [Error Log] in the SD Manager 3.
External device monitoring error
-
*2
X
52
Relay may be welded. Replace the relay.
The relay and the RESET line may not be properly wired.
Check the wiring with the relay.
2-11. External Device Monitoring (EDM)
The relay response time may be exceeding the allowable
delay time. Change the allowable delay time or replace the
relay with one that has an appropriate response time.
2-11. External Device Monitoring (EDM)
4-3-2-1. Interlock/External Device Monitoring
(EDM)/PSDI
Error other than those above
-
*2
X
Error code
other than
those above
An error may have occurred in the internal circuit.
Replace the F3SG-SR.
Description
Checking by
Error code
(HEX)*
Cause and measures
Indicator
SD Manager 3/
SD Manager 3
Mobile APP
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...