Setting with SD Manager 3
4-4-3-5. Instantaneous Block Detection Information
This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
On the top page, click the icon below.
Alternatively, select [Instantaneous Block Detection Information] from the [Maintenance Information] list
in the [Menu] window.
The screen below is displayed.
When the F3SG-SR is in a cascade connection, select a desired sensor segment from the [Target sensor] button
in the top right corner of the screen.
No.
Function name
Description
Initial value
Configurable item
1
Instantaneous Block
Detection Information
Select Enable or Disable for the instantaneous block
detection information display function.
Enable
Enable/Disable
2
Instantaneous Block
Detection Log
Information
Displays blocked beams, presence of vibration, and
accumulated power-on time at the time when
instantaneous block occurred in order from the newest
instantaneous block detection log.
-
-
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...