19
F3SG-SR
User’s Manual
Chapter
1
Ratings and Specifications
Overview and Specifications
E
1-5-2. Intelligent Tap
Model
F39-SGIT-IL3
Applicable sensor
F3SG-SR Series
Performance
Response time
Output ON to OFF and OFF to ON: 44 ms max. each *
*The response time is the time interval between the changes of the states of the sensor
OSSD's and the DO (pin 2).
Startup waiting time
3 s max.
Electrical
Power supply voltage (Vs)
Supplied from external power source: SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
USB bus powered: 5 VDC
Current consumption
85 mA max. (When connecting 24 VDC power supply and IO-Link Master)
Safety outputs (OSSD)/
Auxiliary output
Refer to the ratings and specifications of the F3SG-SR. The safety outputs and
auxiliary output of the Intelligent Tap are directly connected to those of the F3SG-SR.
See 1-5-1. F3SG-SR Series for more information.
Digital output for pin 2
(IO-Link) *
One PNP transistor output
Load current: 100 mA max., Residual voltage: 2 V max., Leakage current: 1 mA max.
The DO is in the OFF state when the safety outputs are in the ON state. The DO is in
the ON state when the safety outputs are in the OFF state. (Regardless of the PNP/
NPN setting of the F3SG-SR)
*For the DO (pin 2) of CN3
Input voltage
RESET, EDM
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *2
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *2
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *2
MUTE A/B,
PRE-RESET,
PSDI *1
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *2
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *2
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *2
*1. PSDI is only available for F3SG-SR.
*2. The Vs indicates a supply voltage value in your environment.
Overvoltage category
(IEC 60664-1)
II
Protective circuit
Output short-circuit protection, Output reverse polarity protection
Insulation resistance
20 M
or higher (500 VDC megger)
Dielectric strength
1,000 VAC, 50/60 Hz (1 min)
Functional
Maintenance Information
Error Log
Power-ON Time
See 2-26. Maintenance Information for more information.
Environmental Ambient
temperature
Operating
-30 to 55 °C (non-icing)
Storage
-30 to 70 °C
Ambient
humidity
Operating
35% to 85% (non-condensing)
Storage
35% to 85%
Degree of protection
(IEC 60529)
IP65, IP67 and IP67G (Covers and cables connected with the Intelligent Tap.)
Vibration resistance
(IEC 61496-1)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock resistance
(IEC 61496-1)
100 m/s
2
, 1000 shocks for all 3 axes
Pollution degree
(IEC 60664-1)
3
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...