99
F3SG-SR
User’s Manual
Chapter
2
Floating Blanking
System Operation and Functions
E
Detection capability
Detection capability for F3SG-SR differs based on the number of floating beams as shown below.
LED indicator status
When Floating Blanking is being enabled, the Blanking indicator turns on.
Limitation for combination with other functions
You can use this function in combination with the Muting, Fixed Blanking, and Warning Zone functions
at the same time with the SD Manager 3. Settings for respective zone have limitations.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
Model
Number of floating beams
configured
Detection capability
Number of blocked beams to
turn safety outputs OFF
F3SG-
SR
-14
-
14 mm
1 beam
1 beam
24 mm
2 beams
2 beams
34 mm
3 beams
3 beams
44 mm
4 beams
4 beams
54 mm
5 beams
n beams
14+(10×n) mm
(n+1) beams
F3SG-
SR
-25
-
25 mm
1 beam
1 beam
45 mm
2 beams
2 beams
65 mm
3 beams
3 beams
85 mm
4 beams
4 beams
105 mm
5 beams
n beams
25+(20×n) mm
(n+1) beams
F3SG-
SR
-45
-
45 mm
1 beam
1 beam
85 mm
2 beams
2 beams
125 mm
3 beams
3 beams
165 mm
4 beams
4 beams
205 mm
5 beams
n beams
45+(40×n) mm
(n+1) beams
F3SG-
SR
-85
-
85 mm
1 beam
1 beam
165 mm
2 beams
2 beams
245 mm
3 beams
3 beams
325 mm
4 beams
4 beams
405 mm
5 beams
n beams
85+(80×n) mm
(n+1) beams
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...