Input/Output Circuit and Applications
6-2-2-4. Standard Muting Mode/Exit-Only Muting Mode with Reset Switch Connector
[Wiring Example]
• When using the Reset Switch Connector (F39-GCNY3), the following functions are not available.
- External Device Monitoring (EDM)
• When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
for more information.
S2
S1
24 VDC
24 VDC
F39-JG C-L
F39-GCNY3
F39-JGR3K-D
XS5F-D421 80-F
F39-JG A-D
IN1
IN2
L1
Wiring for NPN *1
OSSD 1 (Blac
k)
OSSD 2 (White)
24V/0V (Bro
wn)
TEST (Blac
k)
Not used (White)
24V/0V (Bro
wn)
0V/24V (Blue)
0V/24V (Blue)
A
UX (Red)
MUTE B (Pink)
MUTE A (Gr
a
y)
RESET (Y
ello
w)
0V/24V (Blue)
RESET (White)
24V/0V (Bro
wn)
A
UX (Blac
k)
OPERA
TING
RANGE SELECT
INPUT (Y
ello
w) *2
Emitter
Receiver
Safety controller
*3 *4
*5
S3
S4
S1: Test switch
S2: Lockout/interlock reset switch
S3: S4: Muting sensor
L1: Lamp
*1. Reverse the polarity of the power supply when using in the NPN
system. Select a safety controller of PNP or NPN type according to
the system of your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in
Short Mode.
*3. Refer to
6-3. Connectable Safety Control Units
for more information.
*4. The safety controller and the F3SG-SR must share the power supply
or be connected to the common terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. Set the function with the DIP Switches on the Intelligent Tap or the
SD Manager 3, restore the settings to the F3SG-SR, and perform
wiring according to the wiring diagram.
*7. This is the example for the PNP system to stop emission when the
line is connected to 24 VDC and for the NPN to stop emission
when the line is connected to 0 VDC. If TEST switch is not
needed, refer to
: Indicates a switch position
F
unction
Setting
DIP switch
SD Manager 3
EDM
EDM Disabled (factory default setting)
Interlock *6
Manual Reset
[Start interlock] : Enable
[Restart interlock] : Enable
Operating Range
Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Long *6
[Operating Range Selection] : Long mode *6
Standard Muting Mode
N/A
[Muting] : Enable
[Muting mode] : Standard Muting (Installation Example 1/2) *6
Exit-Only Muting Mode *6
N/A
[Muting] : Enable
[Muting mode] : Exit-Only Muting
External Test used
Connect the TEST line of the emitter to 24V/0V via a test switch (NO contact). *7
N/A
[External test signal inversion] : Disable
Optical Synchronization
Open the COM(+) and COM(-) lines of the emitter.
㻠
㻻㻺
㻡
㻻㻺
㻤
㻻㻺
Intelligent Tap
Needed
Timing chart
Beam state: Unblocked
Blocked
MUTE A
Reset switch (S2)
Test switch (S1)
MUTE B
OSSD
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...