222
Chapter
4
Monitoring with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
Reduced resolution zone is displayed in the Information assigned section only when the reduced resolution is enabled.
4-4-1-2. Operating Status Monitoring
This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
On the Top page, click the icon below.
The F3SG-SR enters detecting state, and the safety outputs are turned ON/OFF according to the beam state and
settings.
The screen below is displayed.
6
Information assigned
Shows a function assigned to the beams. The following five functions can be assigned.
-Fixed blanking zone
-Floating blanking zone or Reduced resolution zone
-Warning zone
-Muting zone
Designated beam output zone
7
Select unit of horizontal
axis
Switch the unit of the horizontal axis on the chart between the number of beams and
sensor length.
No.
Function
Description
1
External wiring status
Shows ON or OFF state of signal lines.
2
Sensor Information
When DIP Switch Enabled is selected, it shows a state of DIP Switch settings. When
Configuration Tool Enabled is selected, it shows setting parameters saved in the F3SG-SR.
3
Operating Status
Monitoring
Shows the ON/OFF state of inputs and outputs of the F3SG-SR.
Shows Muting information, Override information, Sequence information, Safety output
information, Push-SW, and Blanking beam unblocked information.
No.
Function
Description
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...