65
F3SG-SR
User’s Manual
Chapter
2
Muting
System Operation and Functions
E
Basic wiring diagram
Installation requirements for muting sensors
• Set the muting sensors so that they can detect all of the passing detection (palettes, automobiles,
etc.). Do not install the muting sensor in a position so that only the front or rear end of the objects is
detected.
• Set the muting sensors so that they detect the objects even when they are loaded on palettes or
other transport devices.
• Also, install the F3SG-SR and muting sensors so that each object passes through all muting sensors
before the next object arrives at the first muting sensor. Also, install all F3SG-SRs and muting
sensors so that no person is able to accidentally enter the hazardous zone while the muting function
is enabled.
• If objects' speeds can vary, the allocation of muting sensors must be taken into consideration.
• Install muting sensors so that they can distinguish between the object that is being allowed to be
passed through the detection zone and a person.
+24 VDC
0V
PNP
NPN
S1
S2
0V
+24 VDC
S1
S2
24V/0V (Brown)
F3SG-SR
receiver
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/PSDI/COM(+)
(Gray)
0V/24V (Blue)
S1, S2: Muting sensor
F3SG-SR
receiver
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/PSDI/COM(+)
(Gray)
0V/24V (Blue)
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...