background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

JA-120PC BUS PIR motion detector with a camera 

JA-120PC BUS PIR motion detector with a camera 

1 / 2 

MMP51105 

The JA-120PC is a component of the JABLOTRON JA-100 system.  

It serves for the detection of human movement in building interiors and 
visual alarm confirmation. The camera takes colour photos with 

 

a resolution of up to 640 x 480 pixels. Taking photos is triggered  
by detecting human movement; this is so that the reason for the alarm 
is always recorded. The camera is equipped with a visible flash for 
taking photos in the dark. The images are saved in the internal memory 
of the detector and then they are forwarded to the control panel.  
And from the control panel they can be sent to MyJABLOTRON or ARC. 
The detector can also take a picture if it is required. The detector takes 
one position in the system and should be installed by a trained 
technician with a valid certificate issued by an authorised distributor. 

The photo-verification can be used only after the 
registration of the system to MyJABLOTRON  
or with subsequent ARC service. 

Installation 

The detector can be installed onto a wall or in the corner of a room. 

There should be no objects which quickly change temperature (electric 
heaters, gas appliances, etc.) or which move (e.g. curtains hanging 
above a radiator) or pets in the detector´s field of sight. It is not 
recommended to install the detector opposite windows or floodlights  
or in places with over-intense air circulation (close to ventilators, heat 
sources, air conditioning outlets, unsealed doors, etc.). There should  
be no obstacles in front of the detector which might obstruct its view. 

When connecting the detector to the system BUS, 
always switch the power off. 

1.

Open the detector cover
(by pushing the tab (4)).
Avoid  touching the PIR
sensor inside (14) –  you
could damage it.

2.

Take out the PCB –
it is held by a tab (9).

3.

Punch through the holes for
the screws and the cable
in the plastic base.
The recommended detector
installation height is 2.5 m
above the floor. 

4.

Insert  the BUS cable and
attach the plastic base
to the wall using screws
(vertically, with the cover
tab facing downwards).

5.

Re-insert the PCB and
connect the BUS cables
to the terminals (11).

Figure: 1 – flash for illumination; 2 – camera lens; 3 – PIR detector lens; 

4 – cover tab 

Figure: 5 – Camera module; 6 – connecting cable; 7 – production code; 

8 – red LED; 9 – PCB tab; 10 – yellow LED; 11 – BUS terminals;  

12 – BUS cable; 13 – tamper contact; 14 – PIR sensor;  

15 – Micro SD memory card; 16 – yellow LED of micro SD card. 

6.

Proceed  according to the control panel installation manual. Basic
procedure:

a.

When the device is switched on, the yellow LED (10) starts
flashing repeatedly to indicate that the module has not been
enrolled into the system.

b.

Go to the 

F-Link

  software, select the required position

in the 

Devices

  window and launch the enrollment mode

by clicking on the 

Enroll

 option.

c.

Click on the option 

Scan/add new BUS devices

, select

the  JA-120PC detector  and double click to confirm – 
the detector is enrolled into the selected position and the yellow 
LED (10) goes off.

d.

If the detector is enrolled as a first camera PIR or the  control 
panel is not connected to MyJABLOTRON, F-link shows
a dialogue window with the question  about  enabling  data 
transfer.  We strictly recommend enabling this option with
the agreement of the customer and confirming this acceptance
by recording it in the system service log with his signature.
Note:  If the transmission is not enabled, images will be saved
only  in the internal memory of the detector and the control
panel. Then it is impossible to send the photos
to MyJABLOTRON or to ARC.

7. Close the detector cover.

Notes:

The detector can also be enrolled into the system by pressing 
the cover tamper sensor (13).

The detector can also be enrolled into the system by entering its
production code  (7)  in the F-Link software  (or with a barcode
scanner). All numbers under the bar code must be entered (1400-
00-0000-0001).

To remove the detector from the system, erase it from its position
in the control panel.

To meet the EN 50131-3 standard it is necessary to secure
the cover tab (4) with the supplied screw.

Detector internal settings 

Settings can be set by 

F-Link

  software  – 

Devices

  tab. When  

at the detector position, use the 

Internal settings

 option to open a dialog 

window where you can configure the settings (

*

 default settings): 

LED movement indication:

 

*Enabled

; allows you to disable movement 

indication with the red LED.  

PIR immunity level:

  Defines false alarm immunity. The 

*Standard

  level 

combines basic immunity with a rapid reaction. The Increased level provides 
higher immunity but the detector reaction is slower. 

PG output reaction:

  select PG outputs, by whose activation picture 

taking is triggered (

*No

, camera does not react to PG). For further info see 

Installation recommendations, cautions.

 

PG-state-triggered picture taking:

 

No flash, *With flash

 

Photo taking during entrance delay: *No flash, With flash

 

Photo taking during alarms: No flash, *With flash 

Flash intensity: Low, *Medium, High – 

in the case of overexposed scene 

with a flash (e.g. in a small room) the intensity of the flash can be reduced. 
For larger spaces it can be increased. 

Caution:

 If there are more detectors 

with the ability to simultaneously  take  a photo  with high intensity flash  
in the system (e.g. when PG output is activated) there is a risk of a one-time 
high  consumption from the BUS, which may cause a short-term power 
outage. We therefore recommend  checking  and counting the total 
consumption. 

Increased number of photos during alarm: 

When enabled, 3 photos 

are sent  instead of 2 during each alarm event, that  means more data 
transfer between the detector and the control panel and between the control 
panel  and  MyJABLOTRON  or ARC. This option is for specific markets  
so we don’t recommend enabling by default. 

Send pre-alarm photos: 

When enabled, the photos are sent also during 

an unconfirmed  alarm, if the repeated or confirmed reaction is set. During 
each entrance delay, if the detector is triggered up to 2 photos can be sent 
even in case of successful unsetting of the system. 

This option will cause a significant increase of the data amount transferred 

to MyJABLOTRON. In case of alarm being not unset (an alarm is triggered) 
the photos are sent automatically regardless of this option. 

Test:

 takes a test picture with a flash and F-link shows it. When the 

Detail

 

button is pressed, F-Link shows the picture with a 640 x 480 px resolution. 

Camera and basic reactions 

The processing of how the camera takes pictures depends 

 

on the settings in the 

F-link

  software  –

Devices

  tab. Choose 

 

the Reaction

 

button on a particular detector line. 

 

Instant:

  During the alarm state the camera can be triggered 3  x (then  

it is auto-bypassed). Every movement takes 3  photos maximum, this 

Reviews: