143
F3SG-SR
User’s Manual
Chapter
3
Teach-in (Fix Blanking / Floating Blanking)
Setting with Intelligent Tap
E
(3) DIP Switch Setting
Before powering the F3SG-SR, set the DIP Switch Position 1 at ON (Lock), Position 2 at ON (DIP
Switch Enabled) and Position6 at ON and 7 at OFF (Fixed Blanking Enabled). And then power the
F3SG-SR.
The Intelligent Tap restores the settings configured by the DIP Switch, to the F3SG-SR. When the
Restoration process is complete successfully, restart the F3SG-SR and check if the F3SG-SR
operates normally.
Block the target Fixed Blanking zone by an object. Do not remove the object until the Step (5) is
complete.
Refer to 3-4. LED Indicators on Intelligent Tap for more information.
(4) Transition to Teach-in Mode
Press and hold the Push Switch (for 3 s or longer) or turn the muting input A ON (for 3 s or longer) to
make the F3SG-SR transition to Teach-in mode.
When the F3SG-SR transitioned to Teach-in mode, the CFG indicator of the F3SG-SR blinks.
(The mode transition to Teach-in mode does not occur if the setting of the DIP Switch is configured as
"Unlock", "DIP Switch Disabled" or "Fixed Blanking Disabled".)
Indicator status in Teach-in mode
(5) Teach-In and Check Processes
When it is ensured that the F3SG-SR is in the Teach-in mode, press the Push Switch (for within 1 s) or
turn the muting input A ON (for within 1 s) to activate the scanning of the blocked area and
automatically configure the setting related to the Fixed Blanking.
*1
The F3SG-SR judges if the setting is valid or not.
If the setting is invalid
*2
, SEQ indicator blinks. In this case, try the steps again from (4).
*1 The Fixed Blanking zone is configured to include one additional beam outside the actually blocked
beams. Two beams on both ends are configured as allowable beams.
F3SG-SR
LED Indicator
Status
SEQ
CFG
ABI
Area blocked by
blocking object is
illuminated in red
OFF
Blinking
Upper
Upper
Lower
11th beam
10th beam
Fixed Blanking zone (4th to 11th beams)
Allowable beam (10th and 11th beams)
5th beam
4th beam
Lower
Allowable beam (4th and 5the beams)
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...