74
Chapter
2
Muting
F3SG-SR
User’s Manual
System Operation and Functions
End conditions
If any of the following condition is satisfied, the MUTING state is released.
• When a workpiece passes the muting sensor A or B and the exit-only muting delay time (4 s: Can
be changed) passes.
• When a workpiece passes the F3SG-SR's detection zone and the muting end wait time (1 s:
configurable) passes.
• The duration of the MUTING state exceeds the muting time limit (60 s: configurable).
The MUTING state is also released when the F3SG-SR enters the LOCKOUT state.
Timing chart
Note. This timing chart shows the case in which the MUTING state was released under the condition of T4 (1 s).
Factory default setting
The MUTING state is also released when the F3SG-SR enters the LOCKOUT state.
Variable
Variable name
Value
Description
T1min
Muting input time limit value
(minimum)
0.1 s
Minimum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is smaller
than this value, a muting sequence error occurs.
T1max
Muting input time limit value
(maximum)
4 s
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting sequence error occurs.
T2
Muting time limit
60 s
The duration time of the Muting function. The MUTING state is
cancelled if it continues for longer than this time limit.
T3
Maximum allowable muting
signal interruption
0.1 s
Maximum duration of a signal interruption allowed in muting
inputs A and B.
T4
Muting end wait time
1 s
Time difference from when the F3SG-SR is unblocked until the
MUTING state is cancelled.
T5
Exit-only muting delay time
4 s
Time difference from when the signal of Muting input A or B is
turned OFF until the MUTING state is cancelled.
ON
OFF
Muting input A
(Muting sensor A1)
Muting input B
(Muting sensor B1)
Unblocked
Blocked
OSSD
ON
OFF
MUTING state
Enabled
Disabled
ON
OFF
Beam state
ABI indicator
ON
OFF
T1min: Muting input time limit value (minimum)
T1max: Muting input time limit value (maximum)
T2: Muting time limit
T3: Maximum allowable muting signal interruption
T4: Muting end wait time
T5: Exit-only muting delay time
T2 max.
80 ms max. *
T3 (0.1 s) max.
T3 (0.1s) max.
T4 (1 s)
T3 (0.1 s) max.
T1min to T1max
T5 max.
Green blinking
Orange
blinking
* 102 ms max. when the
Intelligent Tap is connected
to the F3SG-SR.
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...