![background image](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123270.webp)
242
Chapter
4
Basic Operation of SD Manager 3 Mobile APP
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-5-5. Monitoring with SD Manager 3
4-5-5-1. Incident/Ambient Light Level Monitoring
Tap the following icons on the main screen.
The screen below is displayed.
No.
Function name
Description
1
Light level monitoring operation
Starts or stops monitoring of the selected function.
2
Incident light/ambient light
switching
Select either incident light or ambient light as the monitoring target.
3
Peak and bottom holding
operation
When setting the display, the maximum and minimum values of incident light are
displayed with a water-color and pink lines, respectively.
4
Zone display
Displays the function assigned to the beam.
Each display means the following function.
• DS: Designated beam output zone
• MT: Muting zone
• WR: Warning zone
• FL: Floating blanking zone
or RR: Reduced resolution zone
• FX: Fixed blanking zone
5
Beam display
Displays the beams of the F3SG-SR being monitored.
6
Light level display
Displays the light level and ON/OFF threshold of the selected function.
7
Function switching
The icon of the function which is being monitored is highlighted. Tapping the icon of
the other function switches to the display of the corresponding function.
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...