13
F3SG-SR
User’s Manual
C
ha
pte
r
1
R
ati
ng
s a
nd
S
pe
cif
ica
tio
ns
Overview and Specifications
E
×8 Slow
mode *2
ON to
OFF
Optical
synchronization:
64 to 144 ms
Wired
synchronization:
80 to 168 ms
Optical
synchronization:
64 to 104 ms
Wired
synchronization:
80 to 136 ms
Optical synchronization: 64 ms
Wired synchronization: 80 ms
OFF
to ON
Optical
synchronization:
320 to 720 ms
Wired
synchronization:
400 to 840 ms
Optical
synchronization:
320 to 520 ms
Wired
synchronization:
400 to 680 ms
Optical synchronization: 320 ms
Wired synchronization: 400 ms
*1. Response time when used in one segment system.
1-6-1. List of Models and Response Times
for more information.
*2. Selectable by SD Manager 3.
Effective
aperture angle
(EAA)
(IEC 61496-2)
Type 4
±2.5° max. *
*Emitter and receiver at operating range of 3 m or greater
Light source
Infrared LEDs, Wavelength: 870 nm
Startup waiting time
3 s max.
Electrical
Power supply voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current consumption
for more information.
Safety outputs (OSSD)
Two PNP or NPN transistor outputs (PNP or NPN is selectable by wiring of power
supply.)
Load current: 300 mA max., Residual voltage: 2 V max. (except for voltage drop due to
cable extension), Capacitive load: 1 μF max., Inductive load: 2.2 H max. *1 *2 *3
Leakage current: 1 mA max.(PNP), 2 mA max.(NPN) *4
*1. For the F3SG-
SRA, the load current is 150 mA max. in 2-segment cascade and
80 mA max. in 3-segment cascade.
*2. The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.
*3. The load inductance is the maximum value when the safety output frequently
repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance
becomes larger.
*4. These values must be taken into consideration when connecting elements including
a capacitive load such as a capacitor.
Auxiliary output
One PNP or NPN transistor output (PNP or NPN is selectable by wiring of power
supply.)
Load current: 100 mA max., Residual voltage: 2 V max. *
* The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.
Output
operation
mode
Safety output
Light-ON (Safety outputs are turned to the ON state when the receiver receives an
emitting signal.)
Auxiliary
output
Safety output (Inverted signal output: Enable) (default) (Configurable by SD Manager 3)
Model
F3SG-
SRA
-14
F3SG-
SRB
-14
F3SG-
SRA
-25
F3SG-
SRB
-25
F3SG-
SRA
-45
F3SG-
SRB
-45
F3SG-
SRA
-85
F3SG-
SRB
-85
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...