79
F3SG-SR
User’s Manual
Chapter
2
Muting
System Operation and Functions
E
Timing chart
Basic wiring diagram
Variable
Variable name
Value
Description
T
1max
Muting input time limit value
(maximum)
4 s
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting error occurs.
T
2
Muting time limit
60 s
The duration time of the Muting function. The MUTING state is
cancelled if it continues for longer than this time limit.
T
3
Maximum allowable muting
signal interruption
0.1 s
Maximum duration of a signal interruption allowed in muting
inputs A and B.
T1max: Muting input time limit value (maximum)
T2: Muting time limit
T3: Maximum allowable muting signal interruption
T3 (0.1 s) max.
T1max.
T3 (0.1 s) max.
80 ms max. *
T2 max.
Orange
blinking
Green blinking
Green ON
Orange
blinking
* 102 ms max. when the
Intelligent Tap is connected
to the F3SG-SR.
ON
OFF
Unblocked
Blocked
OSSD
ON
OFF
Enabled
Disabled
ON
OFF
Muting input A
(Limit switch1)
Muting input B
(Limit switch2)
MUTING state
Beam state
ABI indicator
ON
OFF
+24 VDC
0V
PNP
NPN
S1
S2
0V
+24 VDC
MUTE A/PRE-RESET/PSDI/COM(+)
(Gray)
S1
S2
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/PSDI/COM(+)
(Gray)
0V/24V (Blue)
S1, S2
䠖
Muting sensor
F3SG-SR
receiver
F3SG-SR
receiver
24V/0V (Brown)
MUTE B/
COM(-) (Pink)
0V/24V (Blue)
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...