14
Chapter
1
Ratings and Specifications
F3SG-SR
User’s Manual
Overview and Specifications
Input voltage
TEST
Light emission stops when connected to 24 VDC
ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *
OPERATING
RANGE
SELECT
INPUT
Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open
Short: 0 to 3 V (short circuit current: approx. 4.2 mA)
RESET/EDM
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
MUTE A/B ,
PRE-RESET,
PSDI
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
*The Vs indicates a supply voltage value in your environment.
Overvoltage category
(IEC 60664-1)
II
Indicators
for more information.
Protective circuit
Output short-circuit protection
Insulation resistance
20 M
or higher (500 VDC megger)
Dielectric strength
1,000 VAC, 50/60 Hz (1 min)
Functional
Mutual interference prevention
Optical synchronization by Scan Code: in up to 2 sets
Wired synchronization: in up to 3 sets
See 5-1-4. Mutual Interference Prevention for more information.
Cascade connection
Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Test function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-related functions
Interlock
External Device Monitoring (EDM)
Pre-Reset
PSDI
Fixed Blanking/Floating Blanking
Reduced Resolution
Muting/Override
Mutual Interference Prevention
PNP/NPN Selection
Response Time Adjustment
See Chapter 2 System Operation and Functions and Chapter 3 Setting with
Intelligent Tap for more information.
Model
F3SG-
SRA
-14
F3SG-
SRB
-14
F3SG-
SRA
-25
F3SG-
SRB
-25
F3SG-
SRA
-45
F3SG-
SRB
-45
F3SG-
SRA
-85
F3SG-
SRB
-85
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...