164
Chapter
4
Overview and Specifications
F3SG-SR
User’s Manual
Setting with SD Manager 3
4-1-3-2. Connection Procedure When Using USB Connector
1.
Connect the USB connector with the Intelligent Tap as follows.
2.
When you change the settings by using SD Manager 3, turn Positions 1 and 2 as shown below.
3.
Connect the USB connector with the PC’s USB terminal.
When the Intelligent Tap is powered up, the OUT indicator of the Intelligent Tap is illuminated in red or
green.
4.
To restart the Intelligent Tap, unplug the USB connector from the Intelligent Tap and plug it again.
If the Intelligent Tap is connected with F3SG-SR, turn ON the external power supply connected with
the Intelligent Tap again.
After the Intelligent Tap restarts and the power is turned ON, the OUT indicator of the Intelligent Tap is
illuminated in red or green.
USB Type-C
TM
: Indicates the switch position.
1
2
3
4
5
6
7
8
O
N
• Position 1: ON (Lock)
• Position 2: OFF (DIP Switch Disabled)
Intelligent tap
USB Type-C
TM
PC
USB Type-C
TM
[Not connecting F3SG-SR]
[Connecting F3SG-SR]
Power
supply
Turn ON again
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...