Chapter 4
General-Purpose Counter/Timer
DAQ-STC Technical Reference Manual
4-60
©
National Instruments Corporation
Figure 4-28.
CTR_U/D Setup Timing, Internal Timing Mode
Figure 4-29.
CTR_U/D Setup Timing, External Timing Mode
Name
Description
Minimum
Maximum
Tgtclk
CTR_U/D to CTRSRC setup
8
—
All timing values are in nanoseconds.
Name
Description
Minimum
Maximum
Tgtclk
CTR_U/D to CTRSRC setup
8
—
All timing values are in nanoseconds.
CTRSRC
Tgtclk
Counter
2
1
2
3
4
3
2
1
0
Counter TC
CTR_U/D
Tgtclk
CTRSRC
Tgtclk
Counter
2
1
2
3
4
3
2
1
0
Counter TC
CTR_U/D
Tgtclk