Chapter 4
General-Purpose Counter/Timer
DAQ-STC Technical Reference Manual
4-42
©
National Instruments Corporation
G
i_HW_Save_St
i = 0
bit: 12
type: Read
in: Joint_Status_2_Register
address: 29
i = 1
bit: 13
type: Read
in: Joint_Status_2_Register
address: 29
This bit indicates the status of the HW save register for general-purpose counter i:
0: HW save register is tracing the counter.
1: HW save register is latched for later read.
Related bitfields: Gi_Save_Trace.
G
i_HW_Save_Value
i = 0
bits: <0..7>
type: Read
in: G0_HW_Save_Registers
address: 8
bits: <0..15>
type: Read
in: G0_HW_Save_Registers
address: 9
i = 1
bits: <0..7>
type: Read
in: G1_HW_Save_Registers
address: 10
bits: <0..15>
type: Read
in: G1_HW_Save_Registers
address: 11
This bitfield latches the contents of general-purpose counter i on the G_GATE edge
appropriate for the selected gating mode. Refer to Gi_Gating_Mode for a discussion of gating
modes. The eight MSBs are located at the lower address and the 16 LSBs are located at the
higher address. Related bitfields: Gi_Gating_Mode.
G
i_Little_Big_Endian
i = 0
bit: 9
type: Write
in: G0_Command_Register
address: 6
i = 1
bit: 9
type: Write
in: G1_Command_Register
address: 7
This bit selects the load or save register segment to be used for automatic interrupt
acknowledgment:
0: Low register.
1: High register.
Related bitfields: Gi_Read_Acknowledges_Irq, Gi_Write_Acknowledges_Irq.
G
i_Load
i = 0
bit: 2
type: Strobe
in: G0_Command_Register
address: 6
i = 1
bit: 2
type: Strobe
in: G1_Command_Register
address: 7
Setting this bit to 1 loads the contents of the selected load register into general-purpose
counter i. This bit is cleared automatically. Related bitfields: Gi_Load_Source_Select.