Page 58
Speed-controlled mode
The setpoint management system includes a ramp generator. Any of the above-mentioned setpoint
sources can be selected under
Selector: Speed setpoint
and run through the ramp generator. You
can also select another addition setpoint source,
Selector: Correcting setpoint
. This other setpoint
source, however, will not be fed through the ramp generator. The total setpoint is a summation of the
two values. The acceleration and deceleration time of the ramp can be parametrized depending on the
direction.
In the speed setpoint selector menu shown above, you can also activate the torque limitation. This is
symmetrically possible and the limitation source can be selected as desired.
Torque-controlled mode
If you select the
Torque control
tab, you can select any of the above-mentioned setpoint sources
under
Selector: Torque setpoint
. However, the ramp generator and the correcting setpoint are not
available in torque-controlled mode.
You can also activate the torque limitation.
If an analog input is activated as the setpoint source but the menu does not show a line
towards the setpoint, the digital inputs may be activated. (See
chapter Configuring the
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Summary of Contents for DUET_FL 48/10
Page 3: ...ber dieses Handbuch Page 3...
Page 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...