Page 113
6.2 Error management
The error management window and the error window are used for error messages and warnings.
You can open the error management window under
Error/Error management
:
You can use this window to define the way the servo positioning controller should respond to an error.
One of four reaction types is assigned to each of these 64 possible events.
1. The power stage will be switched off (the motor will coast down).
2. Controlled shut-down (the motor will be decelerated to standstill in a controlled manner).
3. A warning will be displayed (the error window will be opened automatically).
4. A warning will not be displayed (i.e. a warning messages will be entered into the error window
but the error window will not be opened automatically).
Some of the events are so serious that the user cannot downgrade them to warning or that a certain
reaction is inevitable. In these cases, the user can select the option button but the servo positioning
controller will correct this entry during the online parameterization.
User Manual DUET_FL „DUET_FL 48/10“