Page 134
No.
Name
Meaning
Scaling
00D8
currc_i_ref_jog1
Jogging setpoint 1 (not supported)
Basic unit current
00D9
currc_i_ref_jog2
Jogging setpoint 2 (not supported)
Basic unit current
00E0
ssel_n_ref
Speed setpoint (input variable of the speed
controller)
Basic unit speed
00E1
ssel_n_act
Actual speed value
Basic unit speed
00E2
ssel_n_act_disp
Actual speed value (filtered) for display in
D2SC
Basic unit speed
00E3
spdc_n_ref_rs232
RS232 speed setpoint
Basic unit speed
00E4
spdc_n_ref_can
CAN speed setpoint
Basic unit speed
00E5
spdc_n_ref_ftd
FTD speed setpoint
Basic unit speed
00E6
spdc_n_ref_profi
Profi speed setpoint
Basic unit speed
00E7
spdc_n_ref_hilf_rs232
Auxiliary RS232 speed setpoint
Basic unit speed
00E8
spdc_n_ref_hilf_can
Auxiliary CAN speed setpoint
Basic unit speed
00E9
spdc_n_ref_hilf_ftd
Auxiliary FTD speed setpoint
Basic unit speed
00EA
spdc_n_ref_hilf_profi
Auxiliary Profi speed setpoint
Basic unit speed
00EB
ssel_ctrl_stat
Speed control configuration
none
00EC
spdc_ctrl_gain
Controller P-gain
Basic unit gain
00ED
spdc_ctrl_time
Controller time constant I-part
Basic unit time
00EE
spdc_sel_n_switch
Speed controller selector for speed setpoint none
00EF
spdc_sel_h_n_switch
Auxiliary setpoint selector for speed
setpoint
none
00F0
ssel_ain0_n_per_volt
Speed setpoint scaling AIN0:
Number of revolutions per volt
Basic unit speed
00F1
ssel_ain1_n_per_volt
Speed setpoint scaling AIN1:
Number of revolutions per volt
Basic unit speed
00F2
ssel_time_c_n_act_filter
Filter time constant of actual speed value
filter
Basic unit time
00F3
ssel_n_acc_pos
Ramp generator - gradient at: Positive
speed - rising edge
Basic unit acceleration
00F4
ssel_n_dec_pos
Ramp generator - gradient at: Positive
speed - falling edge
Basic unit acceleration
00F5
ssel_n_acc_neg
Ramp generator - gradient at: Negative
speed - rising edge
Basic unit acceleration
00F6
ssel_n_dec_neg
Ramp generator - gradient at: Negative
speed - falling edge
Basic unit acceleration
00F7
ssel_lim_sw_ramp_dec
Deceleration for limit switch ramp
Basic unit acceleration
00F8
ssel_enab_off_ramp_dec
Deceleration for quick stop ramp
Basic unit acceleration
00F9
spdc_n_target_speed
Declared speed for message. When n_mel
+/- n_mel_hyst is reached, one bit will be
set in the status word.
Basic unit speed
00FA
spdc_n_target_win_speed
Hysteresis for speed messages:
n_ist = n_mel and n_ist = n_soll
Basic unit speed
00FB
spdc_ramp_brake_max_time Maximum time at quick stop
Basic unit time
00FC
n_ramp_brake_min
Speed at which quick stop was successfully
completed
Basic unit speed
00FD
spdc_n_ref_jog1
Jogging setpoint 1 (not supported)
Basic unit speed
00FE
spdc_n_ref_jog2
Jogging setpoint 2 (not supported)
Basic unit speed
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Summary of Contents for DUET_FL 48/10
Page 3: ...ber dieses Handbuch Page 3...
Page 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...