Page 176
11.18.3
Brake resistance connection [X304 – X305]
Configuration on the device:
2.8 mm FAST-ON female
Mating connector [X304, X305]:
2.8 mm FAST-ON male (insulated externally)
Configuration brake resistance:
R
BR
≥
4,7
Ω
/ P
nom
= 100 W
z.B: metallux PLR 250 5R
R
BR
connect between [X304] und [X305]
Figure 40: Brake resistance connection
Table 34: Pin assignment of connector [X304], [X305]
X30x
Name
Value
Specification
X304
ZK+
+48 V / 15 A
nom.
Intermediate circuit supply (DC bus)
X305
BR-CHOP
0 V / 48 V
Connection to brake resistance transistor