Page 129
0x00040000
No object present with this number (object does not exist)
0x00050000
Not allowed to write object
In addition to the commands for accessing the communication objects, there are also some
commands for controlling the servo positioning controller.
The following table shows the command set used:
Table 22: RS232 command syntax
Command
Response
Description
BAUDbbbb
OK!
Set baud rate
BOOT?
SERVICE / APPLICATION
Status inquiry: Bootloader active?
BUS?
xxxx:BUS:nn:bbbb:mmmm
CAN bus status
INIT!
Turn-on message
Load default parameter set
RESET!
Turn-on message
Cause HW reset
SQT+
xxxx:CQT+
Clear error memory
SAVE!
DONE
Save parameter set in FLASH
SEP!
DONE
Load parameter set from FLASH
TYP?
TYP:dddd
Type inquiry
VERSION?
xxxx:VERSION:dddd
Version inquiry
=iiiiss:dd..
=iiiiss:dd..
Simulation SDO write access
?iiiiss
=iiiiss:dd..
Simulation SDO read access
ERROR!
Unknown command / error
Table 23: Meaning of letters in the command syntax
Letter
Meaning (hexadecimal)
xxxx
Status message
dddd
Data bytes
nn
Node number
bbbb
Baud rate
mmmm
Mode
iiii
Index of CANopen SDObject
ss
Subindex of CANopen SDObject
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Summary of Contents for DUET_FL 48/10
Page 3: ...ber dieses Handbuch Page 3...
Page 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...