Page 127
(1)
These controls are used to control and visualize the cursor of the oscilloscope. When the user
opens the actual oscilloscope window, the current value of the selected channel (cursor position)
is displayed in a numerical form. In this example, channel
CH2
has the value
451 r/min
at the
time
t=30 ms
. The
Cursor
button can be used to switch to another channel.
(2)
These check boxes are used to show and hide the channels in a selective manner.
A selected check box means: This channel is shown.
(3)
This coloured area indicates the current status of the oscilloscope. The following entries are
possible:
inactive
The oscilloscope is not active at present.
start
The oscilloscope is started.
wait for trigger
The system waits for the trigger event.
pretrigger
The system has started to record data for the pretrigger.
trigger found
A trigger event has been found but the system has not started to record data
yet.
data read
The channel data are transferred to the parameterization program.
(4)
The LED indicates the current operating status of the oscilloscope.
A green LED means: The oscilloscope is active.
An inactive oscilloscope is indicated by a red LED.
The
RUN / STOP
check box is used to activate or deactivate the oscilloscope. Activate the
oscilloscope if you want to use it.
(5)
This button can be used to trigger a trigger event manually. The oscilloscope starts recording
data straight away.
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Summary of Contents for DUET_FL 48/10
Page 3: ...ber dieses Handbuch Page 3...
Page 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...