Page 159
Technical data
Ambient conditions and qualification
Parameter
Values
Permissible temperature
ranges
Storage temperature:
-25°C to +70°C
Operating temperature: 0°C to +50°C
+50°C to +70°C with power decrease of 2%/K
Temperature shut-down at about 80°C
Permissible altitude
Up to 1000 m above msl, 1000 to 4000 m above msl with power decrease
Atmospheric humidity
Rel. humidity up to 90%, non-condensing
Type of protection
IP54, depending on method of installation up to IP67
Pollution class
1
CE conformity:
Low voltage directive
EMC directive:
Not applicable
EN 61 800 - 3
Other certifications
UL under preparation
11.13.2
Dimensions and weight
Parameter
Values
Dimensions (H*W*D)
65 x 90 x 100 mm (without mating connector)
Weight
approx. 500 g
11.13.3
Performance data
Parameter
Values
Intermediate circuit voltage
(DC bus voltage)
0 V... 60 V DC (48 V DC rated / 15 A rated)
1)
24V supply
24 V DC [± 20%]
/ 200 mA
2)
+ 700 mA
3)
+ 100 mA
4)
U
Ripple
> 1,5 V
ss, 100Hz
Internally protected through a poly-switch, switches at about 1 A
Braking resistor connection
R
BR
≥
4.7
Ω
/ P
nom
= 20 W...200 W
(only present in DUET_FL 48/10 FB!)
Brake chopper DUET_FL FB
Switching threshold ON:
Switching threshold OFF:
U
chop_on
= 60 V [± 5%]
U
chop_off
= 55 V [± 5%]
1)
An external 15A fuse is required.
2)
Current consumption of the DUET_FL 48/10 without additional wiring
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Summary of Contents for DUET_FL 48/10
Page 3: ...ber dieses Handbuch Page 3...
Page 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Page 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...