Configuring the digital inputs
The menu
Parameters/IOs/Digital inputs
can be used to configure the functionality of the digital
inputs DIN0 - DIN5.
In the positioning mode, a 6 bits wide
position selector
(DIN0 - DIN5) can be configured for
addressing a destination on the basis of the 64 freely programmable targets. In addition, the
Start
input
(DIN6) is of importance for the positioning run.
The digital inputs DIN0 - DIN3 can be used for an offset for the CAN node address.
The functionalities of DIN0 - DIN3 can only be used if the analog inputs AIN0 and AIN1
are used as digital inputs.
If the incremental encoder emulation is active, DIN2 and DIN3 are not available.
5.4 Extended function of the digital inputs (Tipp & Teach)
If the
Tipp & Teach
option is activated in the
Commands
window, the extended function of the digital
inputs can be used.