Transfer Control Instructions
5-31
32-bit program counter to the 24-bit signed value of the
last 24 bits of the Jump or Call instruction. Because it is
signed (2’s complement), the jump can be forward or
backward.
A relative transfer can be to any address within a
16 Mbyte segment. The program counter is combined
with the 24-bit signed offset (using addition or
subtraction) to form the new execution address.
SCRIPTS programs may contain a mixture of direct
jumps and relative jumps to provide maximum versatility
when writing SCRIPTS. For example, major sections of
code can be accessed with far calls using the 32-bit
physical address, then local labels can be called using
relative transfers. If a SCRIPT is written using only
relative transfers it does not require any run time
alteration of physical addresses, and can be stored in and
executed from a PROM.
J
32/64-Bit Jump
22
When this bit is cleared, the jump address is 32-bits wide.
When this bit is set, the jump address is 64-bits wide.
CT
Carry Test
21
When this bit is set, decisions based on the ALU carry bit
can be made. True/False comparisons are legal, but Data
Compare and Phase Compare are illegal.
IF
Interrupt-on-the-Fly
20
When this bit is set, the interrupt instruction does not halt
the SCRIPTS processor. Once the interrupt occurs, the
Interrupt-on-the-Fly bit (
Interrupt Status Zero (ISTAT0),
bit 2) is asserted.
TF
Jump If True/False
19
This bit determines whether the LSI53C1000 branches
when a comparison is true or when a comparison is false.
This bit applies to phase compares, data compares, and
carry tests. If both the Phase Compare and Data
Compare bits are set, then both compares must be true
to branch on a true condition. Both compares must be
false to branch on a false condition.
Summary of Contents for LSI53C1000
Page 6: ...vi Preface...
Page 16: ...xvi Contents...
Page 28: ...1 12 Introduction...
Page 234: ...4 124 Registers...
Page 314: ...6 40 Specifications This page intentionally left blank...
Page 318: ...6 44 Specifications This page intentionally left blank...
Page 344: ...6 70 Specifications This page intentionally left blank...
Page 350: ...6 76 Specifications Figure 6 42 LSI53C1000 329 Ball Grid Array Bottom view...
Page 352: ...6 78 Specifications...
Page 360: ...A 8 Register Summary...
Page 376: ...IX 12 Index...