2K5
1-5-37
1-5-7 Fuser section
(1) Detaching and refitting the fuser unit
Follow the procedure below to check or replace the fuser unit.
Procedure
1. Open the front cover.
2. Remove the clip holder.
3. Remove two screws and remove front left
cover.
Figure 1-5-68
4. Open the left cover 1.
5. Remove two screws and remove the left
cover hook.
Figure 1-5-69
Front left cover
Clip holder
Screw
Screw
Screw
Left cover hook
Left cover 1