2K5
1-5-17
9. Remove the connector of the inverter PWB.
10. Release the clamp and remove the wire.
11. Pull the connector out from the opening on
the rear of the scanner unit.
Figure 1-5-31
12. Remove two films.
13. Remove the wire guide lid.
14. Move the mirror 1 frame to notch position.
Figure 1-5-32
Connector
Inverter PWB
Clamp
Clamp
Opening
Wire
guide
lid
Film
Film
Notch
position
Mirror
1
frame
Notch