2K5
1-5-15
1-5-3 Optical section
(1) Detaching and refitting the exposure lamp
Follow the procedure below to replace the exposure lamp.
Procedure
1. Remove the original cover or the DP.
2. Remove eleven screws and remove the rear
cover.
Figure 1-5-27
3. Remove the clip holder.
4. Remove two screws and remove the front
left cover.
Figure 1-5-28
Screws
(eleven)
Rear cover
Front left cover
Clip holder
Screw
Screw