2K5
1-5-6
(2) Detaching and refitting the MP separation, MP paper feed and MP forwarding pulleys
Follow the procedure below to replace the MP separation, MP paper feed and MP forwarding pulleys.
Procedure
Removing the MP unit
1. Remove two screws and remove the scan-
ner right cover.
Figure 1-5-9
2. Remove four hooks and remove the right
upper cover.
Figure 1-5-10
Screw
Screw
Scanner right cover
Right upper
cover
Hook
Hook
Hook
Hook