(1)
The machine does
not operate when the
main power switch is
turned on.
1. The power cord is not
plugged in properly.
Check the contact between the power plug and the outlet.
2. No electricity at the
power outlet.
Measure the input voltage.
3. Broken power cord.
Check for continuity. If none, replace the cord.
4. Defective main power
switch.
Check for continuity across the contacts. If none, replace the main
power switch.
5. Defective power source
PWB.
With AC present, check for 24 V DC at YC8-4 on the power
source PWB and 5 V DC at YC8-1. If none, replace the power
source PWB.
(2)
The eject motor does
not operate.
1. Poor contact in the con-
nector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
2. Defective drive transmis-
sion system.
Check if the rollers and gears rotate smoothly. If not, grease the
bushings and gears. Check for broken gears and replace if any.
3. Defective eject motor.
Run maintenance item U030 and check if the eject motor oper-
ates. If not, replace the eject motor.
4. Defective engine PWB.
Run maintenance item U030 and check if the eject motor oper-
ates. If not, replace the engine PWB.
(3)
The toner feed motor
does not operate.
1. Poor contact in the con-
nector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
2. Defective drive transmis-
sion system.
Check if the rollers and gears rotate smoothly. If not, grease the
bushings and gears. Check for broken gears and replace if any.
3. Defective toner feed
motor.
Run maintenance item U135 and check if the toner feed motor
operates. If not, replace the toner feed motor.
4. Defective engine PWB.
Run maintenance item U135 and check if the toner feed motor
operates. If not, replace the engine PWB.
(4)
The power source
fan motor does not
operate.
1. Poor contact in the con-
nector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
2. Broken motor coil.
Check for continuity across the coil. If none, replace the motor.
3. Defective motor.
Run maintenance item U037 and check if the motor operates
when the following terminals on the PWB goes low. If not, replace
the corresponding motor.
Power source fan motor: YC6-1 on the power source PWB
4. Defective power source
PWB.
Run maintenance item U037 and check if following terminals on
the PWB goes low. If not, replace the power source PWB.
Power source fan motor: YC6-1 on the power source PWB
Summary of Contents for TASKALFA 300I
Page 1: ...SERVICE MANUAL Published in February 2010 842K5111 2K5SM061 Rev 1 TASKalfa 300i ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...2K5 This page is intentionally left blank ...
Page 22: ...2K5 1 1 8 This page is intentionally left blank ...
Page 196: ...2K5 1 4 52 This page is intentionally left blank ...
Page 252: ...2K5 1 5 56 This page is intentionally left blank ...
Page 274: ...2K5 2 1 20 This page is intentionally left blank ...
Page 310: ...2K5 2 3 28 This page is intentionally left blank ...
Page 347: ...INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 369: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 381: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 391: ...INSTALLATION GUIDE FOR FAX System ...
Page 407: ......
Page 408: ......