Section 8: TSP command reference
Model 2450 Interactive SourceMeter® Instrument Reference Manual
8-190
2450-901-01 Rev. B/September 2013
trigger.model.load() — Empty
This function resets the trigger model.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
trigger.model.load("Empty")
Details
When you load this predefined trigger model, any existing trigger model settings are reset.
Any existing trigger blocks are deleted when you execute this command.
Example
trigger.model.load("Empty")
Reset trigger model settings.
Also see
None
trigger.model.load() — External Trigger
This function loads a predefined trigger model configuration that sets up an external trigger through the digital I/O.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
trigger.model.load("ExternalTrigger",
digInLine
,
digOutLine
,
count
)
trigger.model.load("ExternalTrigger",
digInLine
,
digOutLine
,
count
,
delay
)
trigger.model.load("ExternalTrigger",
digInLine
,
digOutLine
,
count
,
delay,
readingBuffer
)
digInLine
The digital input line (1 to 6); also the event that the trigger model will wait
on in block 1
digOutLine
The digital output line (1 to 6)
count
Number of times to wait for the trigger and send out the trigger
delay
The time in seconds before the measurement is made; default is 0
readingBuffer
The name of the reading buffer, which may be a default buffer
(
defbuffer1
or
defbuffer2
) or a user-defined buffer; defaults to
defbuffer1
Details
This trigger model waits for a digital I/O event to occur, makes a measurement, and issues a notify event.
Also see