Pro I: Signal Conditioning and Interface Modules
ADwin
156
ADwin-Pro
Hardware, manual version 2.9, June 2006
Interface modules
Module
TC-8 ISO
Revision
A
Function
Thermo couple interface
Type
B: 250°C … 1820°C
E: -200°C…1000°C
J: -210°C…1250°C
K: -200°C … 1372°C
N: -200°C…1300°C
R: -50°C … 1768°C
S: -50°C … 1768°C
T: -270°C … 400°C
Accuracy in °C
±
1
Channels
8
Page
Module
CANL-1
CAN-2
Revision
A
A
A
A
Type
CAN interface
CAN-Version
High speed Low speed
High speed Low speed
Interfaces
1
2
Page
Module
PROFI-DP-SL
Inter-SL
Revision
A
A
Type
Fieldbus interface
Fieldbus version
Profibus
Interbus
Size of DP-RAM
2kB
Data exchange rate
9.6kBit/s … 12MBit/s
500kBit/s
Page
Module
RS-232-2
RS-485-2
RS-485-4
Revision
A
A
A
A
Type
RSxxx interface
RSxxx version
RS232
RS485
RS232
RS485
Interfaces
2
4
Data exchange rate
[kBaud]
0.035…
115.2
0.035…
2304
0.035…
115,2
0.035…
2304
Page
Fig. 268 – Overview interface modules