Pro I: Signal Conditioning and Interface Modules
Pro-PROFI-DP-SL Rev. A
ADwin
182
ADwin-Pro
Hardware, manual version 2.9, June 2006
The memory size for the input and output data must be in the range of
0 … 244 bytes. The totoal memory size of both areas must be in the range of
1 … 416 bytes.
shows the possible configuration of a module (slave):
Fig. 314 – Pro-PROFI-DP-SL: Slave configuration
Example
If the module is initialized with 32 bytes input data and 32 bytes output data,
the configuration tool can be configured as follows:
– IN/OUT (16 bytes)
– INPUT (16 bytes)
– OUTPUT (16 bytes)
The two areas with 32 bytes can also be combined differently. But it is impor-
tant that the total of the bytes for the input and the total of the bytes for the out-
put each match with the configuration made during initialization of the module.
If not, the module cannot be part of the data exchange with the bus.
The module supports only the cyclic data exchange. Acyclic data cannot be
transferred.
When the station address is set, indicate the value, which you have set with the
address switches of the module. With another address the master cannot
access the slave and therefore the module cannot exchange data with the bus.
Specifications
Norm
The module is in agreement with the European Standard EN 50170, Volume
2. This norm is provided by the Profibus user organization:
Profibus Nutzerorganisation e.V.
Haid-und-Neu-Str. 7
76131 Karlsruhe, Germany
Phone: +49-72196-58590
Fax : +49-72196-58589
Order number: 0.042