Advanced Functions and Settings: AXIS ALIGNMENT - Axis Alignment Parameter Setting
89
• Press the POSITION key to move the loupe to Axis Point 3.
• Press the ENTER key to store the setting. The following menu appears.
• Press the POSITION key to move the loupe to Axis Point 4.
• Press the ENTER key to store the setting. The following menu appears.
• Use the POSITION key to change the distance value to that of the printed
image, i.e. the distance between point 1 and point 2. The measured value is
shown on the 3rd row. Set the actual distance on the 4th row.
If no changes need to be made, press the ENTER key.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN arrow key to increase or decrease the number for
the distance value.
• Press the ENTER key to store the setting.
The following menu appears:
• Use the POSITION key to change the distance value to that of the printed
image, i.e. the distance between point 1 and point 3. If no changes need to
be made, press the ENTER key.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN arrow key to increase or decrease the number for
the distance value.
• Press the ENTER key to store the setting.
• The READY menu appears, and the plotter is ready to start the cutting
operation.
AXIS POINT 4
.
X=
...
0 mm
Y=
...
0 mm
DISTANCE
POINT 1-2
00099.8 mm
.
OK?
..........
00100.0 mm
.
DISTANCE
POINT 1-3
00101.1 mm
.
OK?
..........
00100.0 mm
.
Summary of Contents for FC5100A-100
Page 1: ...A 75 100 130 150 user manual MANUAL NO FC5100 UM 154...
Page 3: ......
Page 11: ......
Page 27: ...Out of the Box Connecting the Plotter 27...
Page 33: ...Cutters and Holders Blade Length 33...
Page 133: ...Advanced Functions and Settings RS 232C Serial Interface 133...
Page 149: ...Background Settings Background Settings for HP GL 149...