Options: FC5100A Loupe (PHP-61) Loupe
197
FC5100A Loupe (PHP-61) Loupe
The loupe (bombsight) is used to align points for adjustment during axis align-
ment operations, and to indicate the current pen position. The loupe is mounted in
the pen holder.
Attaching the
Loupe
Follow the procedure below to attach the loupe to the pen carriage.
1
Loosen the pen holder screw, and check that the p mark is facing upward.
2
While holding the pen holder upward, push the loupe all the way into the holder
until the flange contacts the pen stopper.
3
Make sure that the pen bracket is mounted firmly over the flange, and then
tighten the screw.
Upper
part
of
pen
holder
Flange
Pen
bracket
Flange