Advanced Functions and Settings: SPEED - Setting the Pen-Up Speed
124
• Press the condition key.
• Set the parameters if necessary, then press the ENTER key to register your
settings.
• Press the F3 key or the F4 key to select the start point or end point. Press
the UP or DOWN ARROW key to set the overcut length. The overcut length
can be set from 0.0mm to 0.9mm in 0.1mm increments.
• Press the ENTER key to register your settings.
SPEED - Setting the Pen-Up Speed
To reduce the overall cutting time, this function allows you to set the traveling
speed of the pen in raised status, separately from the cutting SPEED setting.
• Press the MENU key to select MENU mode.
• Press the NEXT key three times.
• Press the F3 key to select OPTION 1.
• Press the F1 key to select PEN-UP SPEED.
• Press the UP or DOWN ARROW key to sequence through the available
choices.
SET
.............
38
.
CONDITION 6
.........
60
.
....
2
.
CB15U-K30x
...
0
.
OVERCUT
START = 0.2mm
.
END = 0.2mm
.
.
BACKGROUND SETTINGS>
.
OPTION 1>
.
OPTION 2>
.
PEN UP SPEED>
.
OFFSET ANGLE>
.
OFFSET FORCE>
.
STEP PASS>
.
Summary of Contents for FC5100A-100