Advanced Functions and Settings: AUTO REG. MARK - Auto Registration Mark Sensor
101
sured value for the distance between points 1 and 3 is shown on the 3rd row.
Set the actual distance on the 4th row.
Press the RIGHT or LEFT ARROW key to move the cursor. Press the UP or
DOWN arrow key to increase or decrease the number for the distance value.
• Press the ENTER key to store the setting.
• The READY menu appears, and the plotter is ready to start the cutting opera-
tion.
FOUR-POINTS METHOD
The four-points method reads four points, and performs distance adjust-
ment on two axes.
• Select 4POINTS for the MARK SCAN mode, load media in the plotter, and then
press the ALIGNMENT key. The following menu appears
• If you want to skip the registration mark sensing function, press the F2 key
(SKIP) to display the READY menu.
DISTANCE
POINT 1-3
00101.1 mm
.
OK?
..........
00100.0 mm
.
AUTO REG MARK>
*
SKIP>
*
AUTO>
*
MANUAL>
*