Advanced Functions and Settings: AUTO REG. MARK - Auto Registration Mark Sensor
105
Note:
If you select the 2-POINTS method, the Y-axis information is ignored.
Note:
After the plotter senses the first registration mark, it discontinues sensing,
moves to the specified distance and starts searching for the next registration
mark.
Note:
If the distance is set at 0mm, the plotter moves slowly searching for the next
registration mark.
Note:
Always enter a distance value that is shorter than the actual distance between
the registration marks. The plotter will move to the new location and start
searching for the registration mark. If the sensor starts searching
after
it
passes the registration mark, the sensor will not locate the registration mark.
Caution:
If you set the distance of the X-axis to longer than the length of the media, the
plotter will move the required distance and the media will fall off of the plotter.
• Press the ENTER key to register your setting.
• The following menu appears. If you wish to set another parameter, press the key
corresponding to that setting.
Selecting the
Registration
MARK TYPE
The MARK TYPE function is used to select the registration mark pattern. There
are two types of registration patterns that the plotter can sense, pattern 1 and pat-
tern 2.
• Press the ALIGNMENT key.
• Press the F1 key to select AUTO REG. MARK.
MARK SCAN MODE>
*
MARK TYPE>
*
OTHER SETUPS>
*
DISTANCE ADJUST>
*
Mark 1
Mark 2
Pattern 2
Mark 2
Pattern 1
Y
Mark 3
Mark 1
Y
X
Mark 3
Media feed
direction
Enter distance X to the "X=", distance Y to the "Y=".
X
AUTO REG. MARK>
*
SKIP>
*
AUTO>
*
MANUAL>
*
Summary of Contents for FC5100A-100
Page 1: ...A 75 100 130 150 user manual MANUAL NO FC5100 UM 154...
Page 3: ......
Page 11: ......
Page 27: ...Out of the Box Connecting the Plotter 27...
Page 33: ...Cutters and Holders Blade Length 33...
Page 133: ...Advanced Functions and Settings RS 232C Serial Interface 133...
Page 149: ...Background Settings Background Settings for HP GL 149...