Basic GigaVUE H Series Connections and Configuration
83
Removing the Control Card
The GigaVUE-HC3 control card is located in the rear of the chassis behind the fan tray.
It is field replaceable. Since there is only one control card and it is internal, the node
must be powered down. Hot swapping is not possible.
To remove the control card:
1.
If the node is powered on, log in to the serial console port on the node and power it
down gracefully with the
reload halt
command.
2.
Power down the node by unplugging the power cable.
3.
Remove the fan tray as described in
. The control
card is located behind the fan tray as shown in
.
Figure 4-17: Control Card Location
4.
Swing both ejector handles outward as shown in
Figure 4-18: Control Card Ejector Handles