171
Description
FUNC.
EFFECT Setting
Changes transition type to NAM.
13 TRANS-TYPE
M/E1-BKGD
-NAM
14 TRANS-TYPE
M/E2-BKGD
-NAM
Changes transition type to CUT.
15 TRANS-TYPE
M/E1-BKGD
-CUT
16 TRANS-TYPE
M/E1-KEY1-CUT
17 TRANS-TYPE
M/E1-KEY2-CUT
18 TRANS-TYPE
M/E1-KEY3-CUT
19 TRANS-TYPE
M/E2-BKGD
-CUT
20 TRANS-TYPE
M/E2-KEY1-CUT
21 TRANS-TYPE
M/E2-KEY2-CUT
22 TRANS-TYPE
M/E2-KEY3-CUT
Changes transition type to MIX.
23 TRANS-TYPE
M/E1-BKGD
-MIX
24 TRANS-TYPE
M/E1-
KEY1-MIX
25 TRANS-TYPE
M/E1-
KEY2-MIX
26 TRANS-TYPE
M/E1-
KEY3-MIX
27 TRANS-TYPE
M/E2-BKGD
-MIX
28 TRANS-TYPE
M/E2-
KEY1-MIX
29 TRANS-TYPE
M/E2-
KEY2-MIX
30 TRANS-TYPE
M/E2-
KEY3-MIX
Changes transition type to WIPE.
31 TRANS-TYPE
M/E1-BKGD
-WIPE
32 TRANS-TYPE
M/E1-
KEY1-WIPE
33 TRANS-TYPE
M/E1-
KEY2-WIPE
34 TRANS-TYPE
M/E1-
KEY3-WIPE
35 TRANS-TYPE
M/E2-BKGD
-WIPE
36 TRANS-TYPE
M/E2-
KEY1-WIPE
37 TRANS-TYPE
M/E2-
KEY2-WIPE
38 TRANS-TYPE
M/E2-
KEY3-WIPE
Changes transition type to CUT (press) /MIX
(press and hold).
39 TRANS-TYPE
M/E1-BKGD
-CUT/MIX
40 TRANS-TYPE
M/E1-
KEY1-CUT/MIX
41 TRANS-TYPE
M/E1-
KEY2-CUT/MIX
42 TRANS-TYPE
M/E1-
KEY3-CUT/MIX
43 TRANS-TYPE
M/E2-BKGD
-CUT/MIX
44 TRANS-TYPE
M/E2-
KEY1-CUT/MIX
45 TRANS-TYPE
M/E2-
KEY2-CUT/MIX
46 TRANS-TYPE
M/E2-
KEY3-CUT/MIX
Performs same action as pressing PLAY.
47
SEQUENCE PLAY
Performs same action as pressing PAUSE.
48
SEQUENCE PAUSE
Performs same action as pressing SEQ LINK.
49
SEQUENCE AUTO TRANS
Performs same action as pressing AUTO for
the BKGD transition.
50
TRANS-TYPE ME1 AUTO BUTTON
(If TIE function is ON in HVS-16/24OUA )
51
TRANS-TYPE ME2 AUTO BUTTON
(If TIE function is ON in HVS-16/24OUA.)
Toggles GPI USER FLG 01-16 On/Off (GPI
OUT).
52-67
GPI USER FLG01-16
If necessary, a preset delay and / or post delay can be set at the D PRE and D PST
respectively. Setting range for both parameters is 0 – 15 fields. D PRE sets how long
control input is received for initiation to occur. D PST sets how long initiate condition is
held after command received and initiated.
When using GPI IN, set ENABLE to ON. In HVS-16/24OUA, GPI IN can also be set to ON
by pressing GPI IN button in the EFFECT/STILL section of the menu section.
Summary of Contents for HVS-12ROUA