176
16-1-4. Setup Example for AUX OUT Tally
The AUX OUT tally, which indicates the status of an AUX output, can be also used in the
switcher. It would be useful in a case where AUX outputs are used for video source
monitoring. This section shows how to set up an AUX OUT tally. As an example, let us take a
case when Red tally is sent (red tally on) when the video source monitored through AUX1 is
sent to on-air (displayed on the program out).
Conditions:
AUX OUT:
AUX1
On-air bus:
M/E2PGM
Tally color:
RED
Output pin:
Pin1 on TALLY Unit1
Setting:
Open the [FUNCTION - GPI/TALLY - TALLY COLOR] menu.
Turn F1 to select M/E2PGM at SELECT. Press F1 to open the submenu.
Turn F1 to select RED at SELECT. Turn F2 to set ENABLE to ON to enable the selected
tally color.
Press the UP button to return to the [FUNCTION - GPI/TALLY] menu. Then open the
[FUNCTION-GPI/ TALLY - TALLY 1] menu.
Make the setting for the TALLY1 menu as shown below.
FUNCTION
GPI/TALLY TALLY COLOR(2/2)
RED
GREEN
COLOR1
COLOR2
COLOR3
SELECT
1
COLOR4
COLOR5
COLOR6
COLOR7
COLOR8
COLOR9
COLOR10
ENABLE
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FUNCTION
GPI/TALLY TALLY COLOR(1/2)
1. M/E1 PGM
2. M/E1 PST
3. M/E2 PGM
4. M/E2 PST
5. AUX 1
SELECT
3
6. AUX 2
7. AUX 3
8. AUX 4
9. AUX 5
10. AUX 6
11. AUX 7
12. AUX 8
13. AUX 9
14. AUX 10
FUNCTION
GPI/TALLY TALLY1
1 RED
2 RED
3 RED
4 RED
5 RED
P NO.
1
TYPE
TALLY
ENABLE
ON
TALLY
-
AUX01 TLY_FLW
TALLY - IN01
TALLY - IN02
TALLY - IN03
TALLY - IN04
COLOR
RED
INPUT
AUX01
Summary of Contents for HVS-12ROUA