52
5-5-4. AUX LINK
In the AUX-LINK function, the auxiliary outputs are grouped, and the master and slave
outputs are set so all slave output signals can be switched simultaneously by simply selecting
the master output signal. A group consists of one master output and up to four slave outputs.
Five auxiliary output groups can be set. Examples of AUX LINK settings and operation are
shown below.
Creating AUX Output Link Groups
Press the FUNC button in the menu section to display the FUNCTION menu. Turn F1 to
select AUX LINK. Press F1 or the DOWN button to display the AUX LINK sub menu.
Turn F1 to select AUX GROUP under SELECT. Press F1 or the DOWN button to display
the AUX LINK - AUX GROUP submenu.
In the AUX GROUP submenu, turn F1 to select a group to be set from 1-5.
Turn F2 to set the auxiliary output serving as the MASTER. Available outputs are shown
below.
Master Output
AUX01-10,
AUX11-16 (option)
M1PGM, M1PST, M2PGM, M2PST
M1A, M1B, M2A, M2B
Select the auxiliary outputs (up to four) serving as the SLAVE linking to the MASTER
output. Available outputs are shown below.
Slave Output
(Normal link)
AUX01-10,
AUX11-16 (option)
M1PGM, M1PST, M2PGM, M2PST
M1A, M1B, M2A, M2B
The M/E bus outputs can be also linked fully to the MASTER (Full link). In this case,
SLAVE buses always output the same signal as the MASTER and the small letter "s" is
placed in front of the SLAVE names.
Slave Output
(Full link)
sM1PGM, sM1PST, sM2PGM, sM2PST
sM1A, sM1B, sM2A, sM2B
NOTE
The A or B bus cannot be set for AUX LINK output when the PGM or PST bus in the
same M/E is selected. In the same way, the PGM or PST bus cannot be set for AUX
LINK output when the A or B bus in the same M/E is selected.
Both link type slaves, normal link slaves and full link slaves, cannot be selected in the
same M/E.
FUNCTION
AUX LINK
1. AUX GROUP
2. LINK GROUP
SELECT
1
ENABLE
OFF
FUNCTION-AUX LINK
AUX GROUP
1. AUX01 AUX02 AUX03 AUX04 AUX05
2. AUX06 AUX07 ---- ---- ----
3. AUX08 M1PGM ---- ---- ----
4. M1PST AUX09 AUX10 ---- ----
5. M2A sM2B ---- ---- ----
SELECT
1
MASTER
AUX01
SLAVE3
AUX04
SLAVE1
AUX02
SLAVE2
AUX03
SLAVE4
AUX05
Summary of Contents for HVS-12ROUA