4
1-2. OU SETUP Menu
OU SETUP - TOP menu (OU SETUP button)
Submenu
Description
1. BUS CONTROL
Assigns signals to M/E and AUX/KEY bus buttons
2. USER BUTTON
Assigns menu page or function to USER buttons.
3. MODE
Initializes or customizes operation units.
4. FADER
Sets fader lever response.
5. NETWORK
Sets Arcnet connection and selects main unit to control.
Parameter
Description
SELECT
Selects submenus (Press F1 or the DOWN button to select submenus).
OU SETUP sub menus are accessed from the OU SETUP top menu. It is not allowed to move between sub menus.
OU SETUP - BUS CONTROL menu
Submenu
Parameter
Default
Setting Range
Refer to
BUTTON 1
1-34, M/E
5-1-6
SIGNAL IN01
NONE, BLACK, IN01-17, STILL1-STILL4, MATT1, CB,
MATT2, WHITE, L_DVE, IN17-28 (option),
STILL5-STILL6 (option)
NAME IN01
(Signal names set in the MU SETUP-INPUT menu)
INHIBIT OFF
OFF, M/E1, M/E2, M/E1,2
INHIBIT ENABLE
OFF
OFF, ON
AUX BUS SEL
BUS AUX01
AUX01-10, AUX11-16 (option)
ENABLE ON
ON, OFF
DVE TALLY
OFF
ON, OFF
6-9-10
BUS TYPE
M/E1 P/P P/P, A/B
5-1-3
M/E2 P/P P/P, A/B
OU SETUP - USER BUTTON menu
Submenu
Parameter
Default
Setting Range
Refer to
BUTTON 1
1 to 6
4-4-4,
7-2,
14-8,
15-2,
16-3-3
TYPE MENU
MENU, FUNC
FUNC ---
BLACK TRANS
B_TRS
B_TRS, S_PLAY
11-3
OU SETUP - MODE menu
Submenu
Parameter
Default
Setting Range
Refer to
BUTTON CTRL
LIVE
LIVE, EDIT
6-8-3
RATE TYPE
FRM
FRM
FRM, SEC
6-9-1
JOYSTICK ACCEL
LOW, NORMAL, HIGH, ACCEL
15-1-1
SCREEN SAVER
SELECT TIME
OFF, TIME, BALL
MIN 5
1-60
SHIFT SELECT
NORMAL
NORMAL, TOGGLE, OFF
5-1-2
BUZZER
TYPE TYPE1 TYPE1, TYPE2, TYPE3, TYPE4, OFF
15-1-1
VOLUME 20
0-31
TONE NORMAL
LOW, NORMAL, HIGH
BRIGHTNESS 10
1-15
ON AIR TYPE
M/E2
M/E1, M/E2
OU INIT (Select ON and press
F6.)
OFF
OFF, ON
KEYTRS MENU
SHOW
SHOW, HIDE
RENC TYPE
NORMAL
NORMAL, INVERT
TRANS DISP (HVS-16/24OUA)
HOLD
HOLD, PRESS
RENC SPEED
HIGH
NORMAL, HIGH
KEYER FAMNAM
DISBLE
DISBLE, ENABLE
Summary of Contents for HVS-12ROUA
Page 25: ...11 Circuit Max voltage 40V External Device HVS 3800HS S Max load current 100mA...