1
Appendix 1. Menu List
1-1. MU SETUP Menu
MU SETUP - TOP menu (MU SETUP button)
Submenu
Description
1. SYSTEM
Sets the system signal format and adjusts input and output reference signals.
2. INPUT
Sets input signal names.
3. OUTPUT
Sets the safety area of output signals.
4. MODE
KEYER MODE, MATT CLIP and other settings.
5. MATT CLIP
Adjusts internally generated matt signals
6. RS-422
RS-422 baud rate and parity settings.
7. NETWORK
Arcnet and Ethernet settings (option).
8. DATE
Sets date and time.
Parameter
Description
Default
Setting Range
SELECT
Selects submenus (Press F1 or the DOWN
button to select submenus).
- -
X-BUFF
Used to enable the undo operation.
(See section 15-5.)
OFF OFF,
ON
REBOOT
Used to reboot the MU. (See section 15-6.)
OFF
OFF, ON
MU SETUP sub menus are accessed from the MU SETUP top menu. It is not allowed to move between sub menus.
MU SETUP – SYSTEM menu
Submenu
Parameter
Default
Setting Range
Refer to
MODE
FORMAT
HD 1080
1080,
720
3-4
SD NTSC
NTSC,
PAL
RATE
HD
1080 59.94i
60i, 59.94i, 50i, 24p,
23.98p, 24sF, 23.98sF
720
59.94p
60p, 59.94p, 50p
ASPECT
1080, 720
16: 9
4: 3, 16: 9
NTSC
4: 3
4: 3, SQUEEZ, LETTER
PAL
4: 3
4: 3, SQUEEZ
REF IN
HD
1080/59.94i, 1080/50i,
720/59.94p
BB BB,
TRI
S
15-3-1
720/50p BB
BB
1080/60i, 1080/24PsF,
1080/23.98PsF, 1080/24p,
1080/23.98p, 720/60p
TRI S
TRI S
SD BB
BB
REF OUT
HD
1080/59.94i, 1080/50i,
720/59.94p
BB
BB, TRI S, SETUP
720/50p BB
BB
1080/60i,
1080/24PsF, 080/23.98PsF,
1080/24p, 1080/23.98p,
720/60p
TRI S
TRI S
SD
NTSC BB
BB,
SETUP
PAL BB
BB
SC PHS
COARSE
BB
0
-170 to 170
15-3-1
FINE
BB
0.0
-15.0 to 15.0
REF IN
H PHS
TRI S
0
0
15-3-1
BB
1080/50i
-19 to 19
1080/59.94i,
720/59.94p, 720/50p
-15 to 15
NTSC
-15 to 15
PAL
-19 to 19
SC PHS
COARSE
BB
0
-170 to 170
FINE
BB
0.0
-15.0 to 15.0
Summary of Contents for HVS-12ROUA